4 Console Operation
Note: The console has three buttons for easy operation: SET, CH/+ and MIN/MAX button. The
remaining two buttons have no functionality (the same console is used for different products and
therefore, are not used for this product).
4.1 Set Mode
To enter the Set mode, press and hold the SET key for 3 seconds.
1. 12/24 Hour. 12 Hr or 24 hour will begin flashing. Press the CH/+ button to switch between
12 hour and 24 hour display mode. Press the SET button (do not hold) to advance to the next
setting.
2. Hour of Day. The hour of day will begin flashing. Press the CH/+ button to increase the hour,
and the MIN/MAX key to decrease the hour. Press the SET button (do not hold) to advance
to the next setting.
3. Minute of Day. The minute of day will begin flashing. Press the CH/+ button to increase the
minute, and the MIN/MAX button to decrease the minute. Press the SET button (do not hold)
to advance to the next setting.
4. Temperature Units of Measure. The °F or °C icon will begin flashing. Press the CH/+
button to switch between °F and °C. Press the SET button (do not hold) to exist the Set
Mode.
4.2 Min/Max Mode
The Min/Max mode displays the minimum and maximum indoor and outdoor temperature and indoor
humidity (since reset of the unit) for the indoor, remote channel 1, 2 and 3 sensors.
Prior to entering the MIN/MAX mode, press the CH/+ button to select the temperature values you
wish to view.
1. Display Maximum. Press the MIN/MAX button once to display the maximum. The MAX
icon will be displayed.
2. Clear Maximum. To reset the maximum values to the current values, press and hold the
MIN/MAX key for 3 seconds.
3. Display Minimum. Press the MIN/MAX button again to display the minimum. The MIN
icon will be displayed.
4. Clear Minimum. To reset the minimum values to the current values, press and hold the
MIN/MAX key for 3 seconds.
To return to normal mode, press the MIN/MAX button again, or wait 15 seconds for timeout.
4.3 Indoor/Outdoor Channel Selection
Press the CH/+ button to switch the display between OUT remote sensors 1,2 and 3. Channel 1 is
included with the unit. Channels 2 and 3 are optional sensors and purchased separately.
4.4 Sensor Search Mode
If any of the sensor communication is lost, dashes (--.-) will be displayed on the screen. To reacquire
the signal, press and hold the CH/+ button for 3 seconds, and the remote search icon will be